2 spacing units cover this section. The Industrial Commission signed 10 orders on them between 2006 and 2015, and 5 of those changed something. Wells in the smallest unit have reported 591,496 barrels of oil.
At a glance
1,280-acre unit · sections 9 and 16
2,560-acre unit · sections 9, 16, 21 and 28
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section21,280 and 2,560 acres
Orders on record102006 to 2015; 5 changed something, 5 restated the rules
Most wells an order allows in the 1,280-acre unit1stated in 2006
Horizontal wells with laterals in that unit33 active; started 2006 to 2012
Oil those wells have reported591,496barrels, Jan 2003 to Aug 2026
Laterals that still fit3in 1 of the units; a count of space, not a plan
What happened on this land
The 1,280-acre unit was set up in 2006, with 1 horizontal well allowed. 3 horizontal wells have laterals in it, started between 2006 and 2012.
The 1,280-acre unit (sections 9 and 16). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2006
Apr 20, 2006Unit set up
Set up the 1,280-acre unit across sections 9 and 16, with up to 1 horizontal well allowed.
Order 10493 · Case 8933 · Applicant: Continental Resources, Inc.
Sep 15, 2006Pooled
Pooled the 1,280-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 10698 · Case 9109 · Applicant: Continental Resources, Inc.
2010
Dec 16, 2010Unit set up
Set up the 2,560-acre unit across sections 9, 16, 21 and 28, with up to 4 horizontal wells allowed.
Order 14456 · Case 12202 · Applicant: Continental Resources, Inc.
2012
Mar 6, 2012Pooled
Pooled the 2,560-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 17806 · Case 15560 · Applicant: Continental Resources, Inc.
2015
Nov 30, 2015More wells allowed
Raised the 2,560-acre unit from 4 to 26 horizontal wells allowed.
Restated the rules for the 1,280-acre unit.
Order 23705 · Case 21380 · Applicant: Continental Resources, Inc.
5 more orders restated the rules without changing them
Jun 27, 2006: Order 10556 (case 8986), Continental Resources, Inc.
Jul 25, 2006: Order 10607 (case 9031)
Oct 18, 2012: Order 20110 (case 17841), Continental Resources, Inc.
Oct 18, 2012: Order 20223 (case 17954), Continental Resources, Inc.
Sep 11, 2013: Order 21980 (case 19674), Continental Resources, Inc.
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.