3 spacing units cover this section. The Industrial Commission signed 8 orders on them between 2012 and 2026, and 5 of those changed something. Wells in the smallest unit have reported 79,142 barrels of oil.
At a glance
1,280-acre unit · sections 29 and 32
2,560-acre unit · sections 28, 29, 32 and 33
2,560-acre unit · sections 29, 30, 31 and 32
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section31,280 and 2,560 acres
Orders on record82012 to 2026; 5 changed something, 3 restated the rules
Most wells an order allows in the 1,280-acre unit7up from 1 in 2012
Horizontal wells with laterals in that unit10 active; started 2011
Oil those wells have reported79,142barrels, Jan 2003 to Aug 2026
Laterals that still fit5in these units; a count of space, not a plan
What happened on this land
The 1,280-acre unit was set up in 2012, with 1 horizontal well allowed. An order in 2012 raised that to 7. 1 horizontal well has laterals in it, started in 2011.
The 1,280-acre unit (sections 29 and 32). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2012
Apr 20, 2012Unit set up
Set up the 1,280-acre unit across sections 29 and 32, with up to 1 horizontal well allowed.
Order 16834 · Case 14556
Sep 7, 2012More wells allowed
Raised the 1,280-acre unit from 1 to 7 horizontal wells allowed.
Order 20122 · Case 17853 · Applicant: G3 Operating, LLC
Dec 14, 2012Pooled
Pooled the 1,280-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 21403 · Case 19100 · Applicant: G3 Operating, LLC
2014
Jun 16, 2014First on record
First order on record for the 2,560-acre unit over sections 28, 29, 32 and 33.
First order on record for the 2,560-acre unit over sections 29, 30, 31 and 32.
Order 23596 · Case 21292 · Applicant: HRC Operating, LLC
Jun 16, 2014Well count set
Allowed up to 1 horizontal well in the 2,560-acre unit over sections 28, 29, 32 and 33.
Allowed up to 1 horizontal well in the 2,560-acre unit over sections 29, 30, 31 and 32.
Order 23597 · Case 21293 · Applicant: HRC Operating, LLC
3 more orders restated the rules without changing them
Jun 16, 2014: Order 23986 (case 21632)
Aug 6, 2026: Order 35517 (case 32660)
Aug 6, 2026: Order 35662 (case 32736), Enerplus Resources (USA) Corp.
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.