5 spacing units cover this section. The Industrial Commission signed 13 orders on them between 1988 and 2023, and 9 of those changed something. Wells in the smallest unit have reported 5.5 million barrels of oil.
At a glance
640-acre unit · section 7
1,280-acre unit · sections 7 and 18
1,920-acre unit · sections 6, 7 and 8
1,920-acre unit · sections 7, 17 and 18
Units overlap. Each was set up by a different order and has its own well allowance. 1 larger unit is listed below.
Spacing units over this section5640, 1,280, 1,920 and 2,560 acres
Orders on record131988 to 2023; 9 changed something, 4 restated the rules
Horizontal wells with laterals in that unit99 active; started 2011 to 2019
Oil those wells have reported5,460,797barrels, Jan 2003 to Aug 2026
Laterals that still fit1in 1 of the units; a count of space, not a plan
What happened on this land
9 horizontal wells have laterals in it, started between 2011 and 2019.
1988
Feb 5, 1988Pooled
Pooled the 640-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 5096 · Case 4443 · Applicant: Texaco Inc.
1992
Oct 5, 1992Pooled
Pooled the 640-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 6506 · Case 5618 · Applicant: Texaco Exploration And Production Inc.
2011
May 10, 2011Pooled
Pooled the 640-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 16771 · Case 14494 · Applicant: Petro-Hunt LLC
2013
Jul 11, 2013Unit set up
Set up the 1,920-acre unit over sections 7, 17 and 18, with up to 1 horizontal well allowed.
Set up the 2,560-acre unit across sections 5, 6, 7 and 8, with up to 2 horizontal wells allowed.
Order 21095 · Case 18793 · Applicant: Petro-Hunt, LLC
Aug 21, 2013Unit set up
Set up the 1,280-acre unit across sections 7 and 18, with up to 2 horizontal wells allowed.
Order 22524 · Case 20218 · Applicant: Petro-Hunt, LLC
2014
Apr 9, 2014Unit set up
Set up the 1,920-acre unit over sections 6, 7 and 8, with up to 3 horizontal wells allowed.
Raised the 1,920-acre unit over sections 7, 17 and 18 from 1 to 2 horizontal wells allowed.
Restated the rules for the 1,280-acre unit (2 wells).
Order 22329 · Case 20024 · Applicant: Petro-Hunt, LLC
2015
Nov 20, 2015Pooled
Pooled the 1,920-acre unit over sections 6, 7 and 8: the owners' interests across it are combined, and all share in its wells.
Order 26990 · Case 24626 · Applicant: Petro-Hunt, L.L.C.
2016
Feb 17, 2016More wells allowed
Raised the 1,920-acre unit over sections 7, 17 and 18 from 2 to 4 horizontal wells allowed.
Order 26084 · Case 23742 · Applicant: XTO Energy Inc.
2018
Aug 8, 2018Pooled
Pooled the 1,920-acre unit over sections 7, 17 and 18: the owners' interests across it are combined, and all share in its wells.
Order 29198 · Case 26762 · Applicant: Petro-Hunt, L.L.C.
4 more orders restated the rules without changing them
Dec 10, 2014: Order 25487 (case 23156), XTO Energy Inc.
Feb 17, 2016: Order 26825 (case 24459), Petro-Hunt, L.L.C.
Apr 13, 2023: Order 32388 (case 29781)
Jun 22, 2023: Order 32560 (case 29952)
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.