3 spacing units cover this section. The Industrial Commission signed 12 orders on them between 2010 and 2026, and 7 of those changed something.
At a glance
640-acre unit · section 25
2,560-acre unit · sections 25, 26, 35 and 36
2,560-acre unit · sections 25 and 36
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section3640 and 2,560 acres
Orders on record122010 to 2026; 7 changed something, 5 restated the rules
Most wells an order allows in the 640-acre unit3stated in 2012
Horizontal wells with laterals in that unit98 active; started 2009 to 2018
Laterals that still fit1in 1 of the units; a count of space, not a plan
What happened on this land
The 640-acre unit was set up in 2012, with 3 horizontal wells allowed. 9 horizontal wells have laterals in it, started between 2009 and 2018.
The 640-acre unit (section 25). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2010
Dec 27, 2010Pooled
Pooled the 640-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 15958 · Case 13680 · Applicant: Zenergy Operating Co., LLC
2012
Sep 21, 2012Unit set up
Set up the 640-acre unit across section 25, with up to 3 horizontal wells allowed.
Order 19995 · Case 17725 · Applicant: WPX Energy Williston, LLC
2016
Jan 8, 2016First on record
First order on record for the 2,560-acre unit over sections 25, 26, 35 and 36.
First order on record for the 2,560-acre unit over sections 25 and 36, with up to 10 horizontal wells allowed.
Order 26207 · Case 23866 · Applicant: QEP Energy Co.
Jan 12, 2016Pooled
Pooled the 2,560-acre unit over sections 25 and 36: the owners' interests across it are combined, and all share in its wells.
Order 27027 · Case 24663 · Applicant: WPX Energy Williston, LLC
Jan 12, 2016Pooled
Pooled the 2,560-acre unit over sections 25, 26, 35 and 36: the owners' interests across it are combined, and all share in its wells.
Order 27028 · Case 24664 · Applicant: WPX Energy Williston, LLC
Jan 12, 2016Pooled
Pooled the 2,560-acre unit over sections 25 and 36: the owners' interests across it are combined, and all share in its wells.
Order 27029 · Case 24665 · Applicant: WPX Energy Williston, LLC
2026
Jul 8, 2026Well count set
Allowed up to 1 lease-line well in the 2,560-acre unit over sections 25, 26, 35 and 36, running north–south.
Restated the rules for the 2,560-acre unit over sections 25 and 36 (10 wells).
Order 34542 · Case 31805 · Applicant: Enerplus Resources (USA) Corp.
5 more orders restated the rules without changing them
Jan 8, 2016: Order 26776 (case 24409), WPX Energy Williston, LLC
Jan 8, 2016: Order 26917 (case 24551), WPX Energy Williston, LLC
Jun 13, 2016: Order 27248 (case 24856), Marathon Oil Co.
Dec 6, 2017: Order 28446 (case 26032), WPX Energy Williston, LLC
Jan 11, 2022: Order 31536 (case 28985)
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.