2 spacing units cover this section. The Industrial Commission signed 11 orders on them between 2012 and 2026, and 7 of those changed something. Wells in the smallest unit have reported 3.8 million barrels of oil. An order ended 1 of them.
At a glance
1,920-acre unit · sections 4, 5 and 6
3,840-acre unit · sections 4, 5, 6, 7, 8 and 9
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section21,920 and 3,840 acres
Orders on record112012 to 2026; 7 changed something, 4 restated the rules
Most wells an order allows in the 1,920-acre unit8stated in 2014
Horizontal wells with laterals in that unit88 active; started 2015 to 2016
Oil those wells have reported3,774,304barrels, Jan 2003 to Aug 2026
Laterals that still fit1in 1 of the units; a count of space, not a plan
What happened on this land
The 1,920-acre unit was set up in 2014, with 8 horizontal wells allowed. 8 horizontal wells have laterals in it, started between 2015 and 2016.
The 1,920-acre unit (sections 4, 5 and 6). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2012
May 16, 2012Unit set up
Set up the 3,840-acre unit across sections 4, 5, 6, 7, 8 and 9, with up to 17 horizontal wells allowed.
Order 19034 · Case 16765 · Applicant: DAKOTA-3 E&P Co, LLC
May 16, 2012Pooled
Pooled the 3,840-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 19977 · Case 17707 · Applicant: WPX Energy Williston, LLC
2014
Mar 31, 2014Unit ended
Ended the 3,840-acre unit.
Order 24090 · Case 21761 · Applicant: WPX Energy Williston, LLC
Dec 2, 2014Unit set up
Set up the 1,920-acre unit across sections 4, 5 and 6, with up to 8 horizontal wells allowed.
Restated the rules for the 3,840-acre unit.
Order 25479 · Case 23148 · Applicant: WPX Energy Williston, LLC
Dec 24, 2014Pooled
Pooled the 1,920-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 25507 · Case 23176 · Applicant: WPX Energy Williston, LLC
Dec 24, 2014Pooled
Pooled the 3,840-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 25816 · Case 23476 · Applicant: WPX Energy Williston, LLC
2023
Mar 28, 2023Well count set
Allowed up to 1 lease-line well in the 3,840-acre unit, running east–west.
Restated the rules for the 1,920-acre unit (8 wells).
Order 32477 · Case 29868
4 more orders restated the rules without changing them
May 21, 2012: Order 18903 (case 16634), Windsor Energy Group, LLC
Dec 2, 2014: Order 25619 (case 23276), WPX Energy Williston, LLC
Jul 30, 2025: Order 32768 (case 29868)
Feb 9, 2026: Order 35220 (case 32449), Spotted Hawk Development, LLC
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.