2 spacing units cover this section. The Industrial Commission signed 8 orders on them between 2009 and 2024, and 5 of those changed something.
At a glance
1,280-acre unit · sections 1 and 2
1,920-acre unit · part of sections 2, 3, 10, 11, 14 and 15
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section21,280 and 1,920 acres
Orders on record82009 to 2024; 5 changed something, 3 restated the rules
Most wells an order allows in the 1,280-acre unit11up from 7 in 2011
Horizontal wells with laterals in that unit99 active; started 2014 to 2020
Laterals that still fit3in these units; a count of space, not a plan
What happened on this land
The 1,280-acre unit was set up in 2009. An order in 2011 allowed up to 7 horizontal wells. An order in 2017 raised that to 11. 9 horizontal wells have laterals in it, started between 2014 and 2020.
The 1,280-acre unit (sections 1 and 2). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2009
Feb 17, 2009Unit set up
Set up the 1,280-acre unit across sections 1 and 2.
Order 12774 · Case 10804 · Applicant: Peak ND, LLC
2011
May 19, 2011Well count set
Allowed up to 7 horizontal wells in the 1,280-acre unit.
Order 15894 · Case 13618 · Applicant: Enerplus Resources (U.S.A.) Inc.
2017
Jun 22, 2017More wells allowed
Raised the 1,280-acre unit from 7 to 11 horizontal wells allowed.
Order 28248 · Case 25832 · Applicant: Enerplus Resources (USA) Corp.
2019
Apr 10, 2019Unit set up
Set up the 1,920-acre unit across part of sections 2, 3, 10, 11, 14 and 15.
Order 29770 · Case 27324 · Applicant: WPX Energy Williston, LLC
Apr 10, 2019Pooled
Pooled the 1,920-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 29788 · Case 27342 · Applicant: WPX Energy Williston, LLC
3 more orders restated the rules without changing them
May 19, 2011: Order 16843 (case 14565), Enerplus Resources (U.S.A.) Inc.
Apr 10, 2019: Order 29771 (case 27325), WPX Energy Williston, LLC
Oct 16, 2024: Order 33767 (case 31078), Enerplus Resources (USA) Corp.
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
1,280 acresSections 1 and 2
Set up
Feb 2009 · Order 12774
Most wells an order allows
11 · 2017
Last real change
Jun 2017
Wells with laterals inside
9
Laterals that still fit
2
Pool
Mandaree-Bakken
1,920 acresPart of sections 2, 3, 10, 11, 14 and 15
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.