2 spacing units cover this section. The Industrial Commission signed 5 orders on them between 2010 and 2026, and 4 of those changed something. Wells in the smallest unit have reported 748,489 barrels of oil.
At a glance
640-acre unit · section 34
3,840-acre unit · sections 21, 22, 27, 28, 33 and 34
Units overlap. Each was set up by a different order and has its own well allowance.
Spacing units over this section2640 and 3,840 acres
Orders on record52010 to 2026; 4 changed something, 1 restated the rules
Most wells an order allows in the 640-acre unit7up from 2 in 2010
Horizontal wells with laterals in that unit77 active; started 2015
Oil those wells have reported748,489barrels, Jan 2003 to Aug 2026
Laterals that still fit1in 1 of the units; a count of space, not a plan
What happened on this land
The 640-acre unit was set up in 2010, with 2 horizontal wells allowed. An order in 2014 raised that to 7. 7 horizontal wells have laterals in it, started in 2015.
The 640-acre unit (section 34). The line is the highest well count any order has stated so far: a ceiling, not wells drilled. Start dates are spud dates from the state's wells layer.
2010
Nov 24, 2010Unit set up
Set up the 640-acre unit across section 34, with up to 2 horizontal wells allowed.
Order 15508 · Case 13235 · Applicant: QEP Energy Co.
2014
Jul 15, 2014More wells allowed
Raised the 640-acre unit from 2 to 7 horizontal wells allowed.
Order 23891 · Case 21549 · Applicant: XTO Energy Inc.
2015
Sep 18, 2015Pooled
Pooled the 640-acre unit: the owners' interests across it are combined, and all share in its wells.
Order 26163 · Case 23822 · Applicant: XTO Energy Inc.
2026
Oct 12, 2026First on record
First order on record for the 3,840-acre unit across sections 21, 22, 27, 28, 33 and 34.
Order 35518 · Case 32661 · Applicant: Oasis Petroleum North America LLC
1 more order restated the rules without changing them
Oct 12, 2026: Order 35852 (case 32923), Oasis Petroleum North America LLC
The units that cover it
A large unit can hold many more wells than its own order allows, because most of them belong to smaller units inside it. Oil totals overlap for the same reason.
Read by machine, not checked by a person. Order facts come from the signed orders of the North Dakota Industrial Commission, signed through October 21, 2026. The signed order is the rule.
A record of orders, not title or current status. Nothing here says who owns anything, and a later order can change or end a unit.
Well counts are what each order states. A later order can state a smaller number for something narrower, such as one more well. These pages show the highest count and the latest one read; neither is a statement of what is allowed today.
By section. A unit appears when the orders describe its land by section numbers in one township. Units described by lots or quarter sections may be missing, and a unit smaller than its sections covers only part of them.
Oil is as first reported in the free NDIC Monthly Production Reports, January 2003 to August 2026, for horizontal wells with at least 660 ft of lateral inside a unit, whatever formation they produce from. Overlapping units count the same barrels.
Units and wells come from the state's free GIS layers (spacing units of October 17, 2026, wells of November 1, 2026). A well's status is the Industrial Commission's code, not a judgement.
Not legal, engineering or investment advice. Corrections: see contact.